Transformer winding machines have different ways of winding, but many consumers do not have a special understanding of this. Their different winding methods are mainly the following:
1. Precautions for winding a circular coil of a transformer winding machine:
This type of coil is a kind of common coil, mainly composed of an air-core coil and a bobbin coil. The winding method of this type of coil is relatively simple, and the position of the reel is not high, and it can be at the front of the coil. It is also possible to note the following points at the rear of the coil when setting the timing of the transformer winding machine:
(1) Appropriately increase the correction value of the wire diameter according to the process requirements, and adjust the spacing between the wires.
(2) Pay attention to the deformation of the skeleton when setting the wide width. If it is a tire removal coil, the width should be appropriately reduced.
(3) The tension adjustment is moderate, not too large or too small.
2. Note on the winding of the transformer winding machine:
The coil is typically a stator coil of a motor, characterized by a large width and a small diameter, and the wire diameter is generally greater than 0.5 mm. When winding such a coil, attention is paid to the control of the winding speed and the tension control, and the outlet position of the general cable is online. At the back of the circle, such an exit position can avoid edema in the middle of the coil. The winding speed should be adjusted according to the diameter and diameter of the coil. Generally, the coil winding speed is larger, and the faster the winding speed will cause the transformer. The weight of the winding machine and the quality of the coil.